Version numbering for different simulation implementations used

 

VersionNotesSRF genSRF LF dx/dy/dzAWP codeLF Anelastic paraVsminVM dx/dy/dzLF site ampSRF HF dx/dy/dzHF # of raysStress dropHF anelastic paraKappaHF Path durationHF site ampTrans. freqBB merge
gmsim_v10.1GP10 approachspecify the gp gen code0.1kmemod3d versionQs=50Vs; Qp=2Qs500m/s0.1kmCB08; empirical till T=2sec, then linear descrease till 5sec.2km1fixed=5MPaQs=a+bVs0.0451/fc + 0.063RCB081Hz4th order butterworth fourier amps
gmsim_v15.1GP15 approach                           
gmsim_v18.5

gmsim_v15.1 with modified path

duration and long period site amp

                